Differential pressure sensor/transmitter
Pressure medium: air or other non-conductive gas
Accuracy: ±1.0%,±0.4%,±0.25%
Range: unidirectional: 25 Pa to 25000 Pa/bidirectional: ±10 Pa to ±10000 Pa
Signal output: 4-20mA, 0-5Vdc, 0-10Vdc
Overload: Forward and reverse 15PSL (100KPa)
The core component of the Model 175 series differential pressure
sensor/transmitter is a capacitive pressure sensor, which consists of a
stainless steel diaphragm with a fixed electrode forming a capacitor
whose value varies with pressure. Using the company's special patented
technology carefully designed sensor sensors and unique detection
circuit to ensure good temperature performance and long-term stability
of the product.
The Model 175 differential pressure
sensor/transmitter can be used to measure differential or gauge pressure
with outputs of 0-5V, 0-10V, 4-20mA, and can also be customized for
other outputs. The accuracy of Model 175 was ±1.0%FS, 0.4%FS or 0.25%FS
at room temperature. The temperature compensation ranges from 4 ℃ to
77℃, and the temperature effect is less than ±0.05%FS/℃.
Model
175 has excellent performance-price ratio, widely used in HVAC,
environmental pollution control, clean engineering, medical instruments
and equipment, oven pressurization and furnace pressure control, natural
gas, gas pipe network monitoring, underground ventilation and power
plant wind pressure monitoring and other fields.
LED pressure status display
One key reset button
Removable European junction box
True zero output of voltage
The positive/negative pressure end can withstand at least 100kPa overload without damage
Full protection of misconnection
Environmental protection design, in line with ROHS standards
Minimum pressure range of 10Pa
Parameter | Standard | Special selection | Special selection |
Accuracy RSS*(under constant temperature) | ±1.0%FS | ±0.40%FS | ±0.25%FS |
nonlinearity(best fitting line) | ±0.97%FS | ±0.37%FS | ±0.24%FS |
lag | ±0.20%FS | ±0.10%FS | ±0.05%FS |
non-repeatability | ±0.10%FS | ±0.10%FS | ±0.05%FS |
Temperature effect | |||
Zero point/Full range offset(/℃) | ±0.05%FS | ±0.03%FS | ±0.02%FS |
Compensation range | 4℃ to 77℃ | ||
Maximum static pressure | 15PSI(100kPa) | ||
Overload | Both positive and negative are 15PSI(100kPa) | ||
Stability ratio | ±0.5% FS/YR | ||
Preheat | 5 seconds to reach the performance specification | ||
Installation position effect | When factory calibration, the sensor is placed vertically. In order to ensure accuracy, necessary fine tuning should be made when installing other positions at zero point |
Environmental and mechanical parameters | |
Operating temperature | -18℃ to 77℃ |
Storage temperature | -40℃ to 85℃ |
LED Indication | None: The power supply is not connected Green: works properly Red: Overvoltage, or during zero calibration Blinking green/red: Damaged, unable to complete zero calibration |
Electrical connection | Detachable European junction panel, 14-26 AWG |
Pressure connection | 3/16"、φ8 brass tower pressure connection(optional) |
Output regulation | Press the zero button to clear zero and fine-tune the full range through the potentiometer |
Pressure medium | Air or other non-conductive gas |
Shell | Stainless steel/PC+ABSalloy,94V-0 |
Weight | 108g |
Installation | Refer to the product specification for outline dimensions as shown in Figure 1 |